General Refrigeration Controller  
Download Broucher
 
Instruction manual
The CX family (32x74mm) has new functions plus an innovative and attractive design. The revolutionary introduction of 6 keys allows the user direct access to all main functions rapidly and intuitively, while the display with illuminated icons allows an instant view of the machine’s status.
 
Regulation stop by auxiliary probe (beer dispenser applications); it is possible to supervise the tube temperature, stopping the compressor when the temperature becomes too low, and restarting when the correct values have been restored.
Max and Min temperature or HACCP function.
Virtual probe for air on / air off application; used in multideck applications where it is important to regulate temperature using the average of 2 temperatures.
Condenser temperature management to prevent critical situations in the system.
Real time clock.
TTL serial connection for monitoring systems (direct for XR35/75/77CX or through XJ485CX).
 
Features :
    XR30CX   XR35CX   XR64CX   XR70CX   XR72CX   XR75CX
Display : n digits   ± 3 d.p.
12,24Vac/dc
  ± 3 d.p   ± 3 d.p   ± 3 d.p   ± 3 d.p   ± 3 d.p
Power Supply   24,110,230Vac
9÷40 Vdc
  110, 230Vac   24,110,230Vac
24,110,230Vac
  24,110,230Vac
24,110,230Vac
  24,110,230Vac  12Vac/dc   110,230Vac
Probe inputs                        
Thermostat   NTC/PTC   NTC/Pt1000   NTC/PTC NTC/PTC   NTC/PTC NTC/PTC   NTC/PTC NTC/PTC   NTC/Pt1000
Defrost       NTC/Pt1000   NTC/PTC NTC/PTC   NTC/PTC NTC/PTC   NTC/PTC NTC/PTC   NTC/Pt1000
Thermostat       NTC/PTC   NTC/PTC   NTC/PTC   NTC/PTC   NTC/PTC
Defrost               NTC/PTC   NTC/PTC    
Defrost 2           NTC/PTC NTC/PTC           PTC
Condenser   NTC/PTC on Hot Key   NTC/Pt1000   NTC/PTC on Hot Key   NTC/PTC on Hot Ke   NTC/PTC on Hot Key   NTC/Pt1000
Digital Inputs                        
Alarm, start defrost, AUX, door switch, pressure switch, probe   config   config   config   confi g   config   config
Alarm, start defrost, AUX, door switch, pressure switch       confi g               confi g
Relay outputs                        
Compressor   8A, 20A opt   8A, 16A opt   8A,16A opt 16A   8A, 16A opt 16A   8A, 16A opt 16A   8A,16A opt
Compressor 2                   8A 16A    
Defrost           8A 16A   8A 16A   8A 16A   8A
Defrost 2           8A 16A            
Fans           5A 16A   5A 16A   5A 16A   5A
Light or Alarm   8A   8A       8A   16A       8A
Other                        
Hot Key output   pres   pres   pres   pres   pres   pres
Remote display output   X-REP opt   X-REP   X-REP opt   X-REP opt   X-REP opt   X-REP
Serial Output   TTL   RS485   TTL   TTL   TTL   RS485
Buzzer   opt   opt   opt   opt   opt   opt
Real time clock   opt   opt       opt        
 
Line Diagram :   Accesories
 
 
 
 