Regio - Room Controller / Thermostat |
|
|
|
|
|
|
|
|
|
Regio is a line of room controllers which can handle a great variety of applications, e.g. heating and cooling, ventilation, lighting, humidity, CO2, fans and blinds. With Regio, you can create anything from stand-alone systems for managing the functions in one room to large integrated SCADA systems. |
|
Regio has following 3 series: |
|
- Regio maxi (Freely programmable Thermostats with communication
and web interface) |
- Regio midi (Pre-programmed Thermostats with communication) |
- Regio mini (Pre-programmed Stand alone Thermostats) |
|
|
Regio tool software for PC monitoring |
|
Award wining design in international Forum. |
|
|
|
Regio Maxi ( Freely Programmable Thermostats with communication / web interface) |
|
|
|
F = Fan control (3-speed)
T = TCP/IP communication |
|
Inputs/outputs (I/Os) |
|
|
|
RCP100 / RCP100T |
|
RCP100F / RCP100FT |
|
RCP200 / RCP200T |
|
RCP200F / RCP200FT |
|
AI |
|
2 |
|
2 |
|
2 |
|
2 |
|
DI |
|
3 |
|
3 |
|
3 |
|
3 |
|
CI |
|
1 |
|
1 |
|
1 |
|
1 |
|
AO |
|
- |
|
- |
|
2 |
|
2 |
|
DO, 230 V AC relay for fan |
|
control |
|
- |
|
3 |
|
3 |
|
DO, 24 V AC |
|
4 |
|
4 |
|
2 |
|
2 |
|
|
Models with communication via RS485
(Modbus or EXOline) /TCP |
|
Type |
|
Fan control |
|
Output signal |
|
Can be combined with |
|
RCP100 / T |
|
- |
|
3-point or on/off |
|
RU, RU-O, RU-DO, RU-DOS |
|
RCP100F / FT |
|
Yes |
|
3-point or on/off |
|
RU-F, RU-FO, RU-DFO, RU-DOS |
|
RCP200 / T |
|
- |
|
0...10 V DC |
|
RU, RU-O, RU-DO, RU-DOS |
|
RCP200F / FT |
|
Yes |
|
0...10 V DC |
|
RU-F, RU-FO, RU-DFO, RU-DOS |
|
|
|
|
|
|
|
Regio Midi ( Pre-programmed Room Thearmostats with communication) |
|
|
|
Regio Midi are controllers with a built-in sensor and an RS485 communication port. Controllers in different rooms can be connected to a bus line enabling communication with a central SCADA system via RS485 (EXOline or Modbus). |
|
C = Communication, EXOline or Modbus |
D = Display |
F = Fan control (3-speed) |
H = Hidden setpoint |
O = Occupancy button |
T = 3-point output |
C (at the end) = CO2 input |
|
|
|
|
|
|
Models with 0...10V DC, on/off or 3-point output with communication |
|
Type |
|
Display |
|
Occupancy button /Forced ventilation |
|
Fan control |
|
Setpoint
knob |
|
Hidden setpoint |
|
Output |
|
RC-C |
|
- |
|
- |
|
- |
|
Yes |
|
- |
|
0...10 V DC or on/off |
|
RC-CO |
|
- |
|
Yes |
|
- |
|
Yes |
|
- |
|
0...10 V DC or on/off |
|
RC-CH |
|
- |
|
- |
|
- |
|
- |
|
Yes |
|
0...10 V DC or on/off |
|
RC-CDO |
|
Yes |
|
Yes |
|
- |
|
- |
|
- |
|
0...10 V DC or on/off |
|
RC-CF |
|
- |
|
- |
|
Yes |
|
Yes |
|
- |
|
0...10 V DC or on/off |
|
RC-CFO |
|
- |
|
Yes |
|
Yes |
|
Yes |
|
- |
|
0...10 V DC or on/off |
|
RC-CDFO |
|
Yes |
|
Yes |
|
Yes |
|
- |
|
- |
|
0...10 V DC or on/off |
|
RC-CDOC |
|
Yes |
|
Yes |
|
- |
|
- |
|
- |
|
0...10 V DC or on/off |
|
RC-CTH |
|
- |
|
- |
|
- |
|
- |
|
Yes |
|
3-point |
|
RC-CT |
|
- |
|
- |
|
- |
|
Yes |
|
- |
|
3-point |
|
RC-CTO |
|
- |
|
Yes |
|
- |
|
Yes |
|
- |
|
3-point |
|
RC-CDTO |
|
Yes |
|
Yes |
|
- |
|
- |
|
- |
|
3-point |
|
|
|
Inputs/outputs (I/Os) |
|
|
|
RC-C |
|
RC-CO |
|
RC-CH |
|
RC-CDO |
|
RC-CF |
|
RC-CFO |
|
RC-CDFO |
|
RC-CDOC |
|
RC-CTH |
|
RC-CT |
|
RC-CTO |
|
RC-CDTO |
|
AI |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
2 |
|
1 |
|
1 |
|
1 |
|
1 |
|
DI |
|
2 |
|
2 |
|
2 |
|
2 |
|
2 |
|
2 |
|
2 |
|
2 |
|
2 |
|
2 |
|
2 |
|
2 |
|
DO |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
0 |
|
1 |
|
1 |
|
1 |
|
1 |
|
UO |
|
2 |
|
2 |
|
2 |
|
2 |
|
2 |
|
2 |
|
2 |
|
3 |
|
- |
|
- |
|
- |
|
- |
|
Total number |
|
7 |
|
7 |
|
7 |
|
7 |
|
10 |
|
10 |
|
10 |
|
7 |
|
9 |
|
9 |
|
9 |
|
9 |
|
|
|
|
|
Regio Mini ( Pre-programmed Stand alone Room Thermostats) |
|
|
|
The Regio Mini controllers are pre-programmed and can be configured for a specific application via the display or dipswitches (in most cases, though, the default settings can be applied). The controllers have a built-in temperature sensor. Alternatively, an external temperature sensor can be connected. |
|
D = Display |
F = Fan control (3-speed) |
H = Hidden setpoint |
O = Occupancy button |
T = 3-point output |
|
|
|
|
|
|
|
|
Models with 0...10V DC, on/off or 3-point output without communication |
|
Type |
|
Display |
|
Occupancy button /Forced ventilation |
|
Fan control |
|
Setpoint knob |
|
Hiddensetpoint |
|
Output |
|
RC |
|
- |
|
- |
|
- |
|
Yes |
|
- |
|
0...10 V DC or on/off |
|
RC-O |
|
- |
|
Yes |
|
- |
|
Yes |
|
- |
|
0...10 V DC or on/off |
|
RC-H |
|
- |
|
- |
|
- |
|
- |
|
Yes |
|
0...10 V DC or on/off |
|
RC-DO |
|
Yes |
|
Yes |
|
- |
|
- |
|
- |
|
0...10 V DC or on/off |
|
RC-F |
|
- |
|
- |
|
Yes |
|
Yes |
|
- |
|
0...10 V DC or on/off |
|
RC-FO |
|
- |
|
Yes |
|
Yes |
|
Yes |
|
- |
|
0...10 V DC or on/off |
|
RC-DFO |
|
Yes |
|
Yes |
|
Yes |
|
- |
|
- |
|
0...10 V DC or on/off |
|
RC-T |
|
- |
|
- |
|
- |
|
Yes |
|
- |
|
3-point |
|
RC-TO |
|
- |
|
Yes |
|
- |
|
Yes |
|
- |
|
3-point |
|
RC-DTO |
|
Yes |
|
Yes |
|
- |
|
- |
|
- |
|
3-point |
|
|
|
Inputs / outputs (I/Os) |
|
|
|
RC |
|
RC-O |
|
RC-H |
|
RC-DO |
|
RC-F |
|
RC-FO |
|
RC-DFO |
|
RC-T |
|
RC-TO |
|
RC-DTO |
|
AI |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
DI |
|
2 |
|
2 |
|
2 |
|
2 |
|
2 |
|
2 |
|
2 |
|
2 |
|
2 |
|
2 |
|
UI |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
DO |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
1 |
|
UO |
|
2 |
|
2 |
|
2 |
|
2 |
|
2 |
|
2 |
|
2 |
|
- |
|
- |
|
- |
|
Total number |
|
7 |
|
7 |
|
7 |
|
7 |
|
10 |
|
10 |
|
10 |
|
9 |
|
9 |
|
9 |
|
|
|
|
|
|
Room Controllers/Thermostats |
|
|
|
Fan-coil thermostat with on/off or 3-point outputs |
|
Technical data |
|
|
|
Supply voltage |
|
230 V AC ±10 %, 50/60 Hz |
|
Power Consumption |
|
<3 VA |
|
|
|
|
Description |
|
Installations |
|
Change-over function |
|
Type |
|
Room thermostat for fan-coil applications |
|
2- or 4-pipe |
|
Automatic |
|
RCF-230D/TD |
|
(T = on/off and TD = point output) |
|
2-pipe |
|
Manual |
|
RCFM-230D/TD |
|
|
Fan-Coil Controller For 0...10v Control Signal |
|
|
|
Technical data |
|
|
|
Supply voltage |
|
230 V AC ±10 %, 50/60 Hz |
|
Power Consumption |
|
<3 VA |
|
|
|
|
Description |
|
Installations |
|
Change-over function |
|
Type |
|
Room thermostat for fan-coil applications
(AD= 0... 10V output) |
|
2- or 4-pipe |
|
Automatic |
|
RCF-230D/AD |
|
|